Brand Name : RISING
Model Number : RS1200
Certification : ISO CE
Place of Origin : China
MOQ : 1 SET
Payment Terms : L/C, L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability : 500 SET PER Month
Packaging Details : Wooden package
RS1200 Relay Protection Device Microcomputer Relay Protection Tester
| Relay protection type | 
 Test items | 
 Suggested test module | 
 Remark | ||
| Line protection | 
 Multistage | ||||
| Over /(under) voltage | |||||
| 
 Sequence component voltage and current | |||||
| 
 Frequency device | |||||
| Power direction protection | |||||
| Reclosing and conversion fault | Corresponding test item | Complete set test, line protection, state series, 6-35KV line protection integrated test | It's required to test the synchronization check and no-voltage check and use Ux as the voltage output of connected side while the 1200 tester uses Ua instead of Ux for test. | ||
| Distance and zero sequence | Distance and zero sequence fixed value verification | Distance and zero sequence, line protection, complete set test, AC test | Both "distance and zero sequence" and "line protection" can automatically simultaneously test the distance and zero sequence fixed value of multiple stages, various fault types and various phases. | ||
| Impedance characteristics | Impedance characteristics | ||||
| Power frequency variation impedance | Fixed value verification | Distance and zero sequence, line protection | 10~15A The fault current should be large enough such as 10-15A (in the case of CT of 5A system) | ||
| Overcurrent protection of composite voltage blocking (direction) | Overcurrent, low voltage, negative sequence voltage, angle of sensitivity, etc | AC test, 6-35KV line protection integrated test | The "low voltage" and "negative sequence voltage" under protection will be input from different terminals and the wiring needs to be changed at test | ||
| Low cycle, low voltage deloading device | Corresponding test item | Frequency and high and low cycle, 6-35KV line protection integrated test | If other conditions are all met but the device still fails to operate, please confirm whether the device needs current input and switch contact at the same time | ||
| Generator protection | Differential protection | Proportion braking characteristics | Differential protection, differential fixed value, AC test | As to generator differential protection, when testing with the "differential protection", it can be seen as power transformer protection with the wiring type as Y/Y and the high and low voltage side balance coefficient as 1 | |
| "Differential protection" focuses on curve characteristics search, while "differential fixed value" module focuses on differential fixed value test and the combination of both provides a comprehensive test of differential protection | |||||
| Harmonic braking characteristics | Differential protection, differential fixed value, AC test | ||||
| Field loss protection | Corresponding test item | AC test | Attention should be paid to the angle of output voltage and current in the test. | ||
| Excitation protection | |||||
| Overcurrent protection of composite voltage blocking (direction) (reserve) | Corresponding test item | Please refer to the above "line protection" section | Please refer to the above "line protection" section | ||
| Other protection | Automatic synchronized device | Corresponding test item | Synchronization test | When the automatic adjustment test is conducted, wiring shall be made according to the manual for each switch input test | |
| Bus differential protection | Corresponding test item | AC test | Please refer to the instructions on BP-2B and RCS-915 in "NARI Part Protection" of Appendix 6 | ||
| Line differential protection | First determine whether the device forms "self-loop" before test. If so, the protection operating value should be equal to half of its setting value | 
—AC output current
When six-phase current is output, each phase outputs (effective value) 0-30A with output accuracy 0.2 class
When three-phase current is output, each phase outputs (effective value) 0-60A
Six-phase paralleling output current (effective value) 0-180A
Long-time allowable work value of phase current (effective value) 10A
Maximum output power of phase current 300VA
Maximum output power in the case of the Maximum output of six-phase paralleling current 1,000VA
Allowable working hours in the case of the maximum output of six-phase paralleling current 10s
Frequency range (fundamental wave) 0-1,000Hz
Number of harmonic 1-20 times
—DC output current
Output current 0-±10A/each phase output accuracy 0.5 class
Maximum output load voltage 20V
—AC output voltage
Phase output voltage (effective value) 0-120V output accuracy 0.2 class
Line output voltage (effective value) 0-240V
Phase voltage/line output voltage power 80VA/100VA
Frequency range (fundamental wave) 0-1,000Hz
Number of harmonic 1-20 times
—DC output voltage
Phase output voltage amplitude 0-±160V with output accuracy 0.5 class
Line output voltage amplitude 0-±320V
Phase voltage/line output voltage power 70VA/140VA
—Switching value
8-route switching value input
Idle contact 1-20mA, 24V
Electric potential contact connects "0": 0-+6V;“1”:+11V - +250V
4 pairs of switching value output DC: 220 V/0.2A;AC:220V/0.5A
-Time measurement range
0.1ms-9999s, measurement accuracy<0.1mS
|   | 
| Microcomputer Relay Protection Tester Images | 
 RSPDF-1000 DC Ground Fault Tester , Protective Relay Test Equipment
                                                                                    
                        
                        
                        
                                                            RSPDF-1000 DC Ground Fault Tester , Protective Relay Test Equipment
                                                    
                        
                     Single Phase Relay Protection Tester RSRPD 100h Maximum Measuring Range
                                                                                    
                        
                        
                        
                                                            Single Phase Relay Protection Tester RSRPD 100h Maximum Measuring Range
                                                    
                        
                     RS702 Relay Protection Device Micro Computer Control Automatic 3 Phase Relay
                                                                                    
                        
                        
                        
                                                            RS702 Relay Protection Device Micro Computer Control Automatic 3 Phase Relay
                                                    
                        
                     Durable Relay Protection Device Tester With 0 ~ 250v Potential Contacts
                                                                                    
                        
                        
                        
                                                            Durable Relay Protection Device Tester With 0 ~ 250v Potential Contacts
                                                    
                        
                     Rs702 Relay Protection Device 20~1000hz Frequency Range 1 Year Warranty
                                                                                    
                        
                        
                        
                                                            Rs702 Relay Protection Device 20~1000hz Frequency Range 1 Year Warranty
                                                    
                        
                     Microcomputer Relay Protection Testing Device RS702 0.5 Class Output Accuracy
                                                                                    
                        
                        
                        
                                                            Microcomputer Relay Protection Testing Device RS702 0.5 Class Output Accuracy
                                                    
                        
                     3 Phase Protection Relay Tester RS702 Secondary Current Injection Test Set
                                                                                    
                        
                        
                        
                                                            3 Phase Protection Relay Tester RS702 Secondary Current Injection Test Set
                                                    
                        
                     White Relay Protection Device Standard Four Phase Voltage Three-phase Output
                                                                                    
                        
                        
                        
                                                            White Relay Protection Device Standard Four Phase Voltage Three-phase Output
                                                    
                        
                     RS1200 Microcomputer Protective Relay Tester With ISO Certification
                                                                                    
                        
                        
                        
                                                            RS1200 Microcomputer Protective Relay Tester With ISO Certification
                                                    
                        
                     RS1200 Relay Protection Device Microcomputer 6 Phase Relay Protection Tester
                                                                                    
                        
                        
                        
                                                            RS1200 Relay Protection Device Microcomputer 6 Phase Relay Protection Tester